how to fix thermo king reefer code 32?

Author:

Published:

Updated:

thermo king reefer code 32

Affiliate Disclaimer

As an affiliate, we may earn a commission from qualifying purchases. We get commissions for purchases made through links on this website from Amazon and other third parties.

Did you know that Thermo King reefer code 32 is a common alarm code that indicates low refrigeration capacity in the unit? This alarm code often goes hand in hand with code 26, which signifies poor cooling. When faced with these alarm codes, it’s crucial to address them promptly to ensure the efficient and effective operation of your Thermo King reefer.

Thermo King reefer units, like the SL3000, may display alarm code 32, which points to low refrigeration capacity. To troubleshoot this issue and get your reefer back on track, it is important to check the refrigerant charge, inspect various sensors, and monitor the temperature manually throughout the day to catch any alarms. Swift action is necessary to prevent further complications and maintain the proper functioning of the Thermo King reefer.

Key Takeaways

  • Thermo King reefer code 32 indicates low refrigeration capacity.
  • Code 26 often accompanies code 32 and signifies poor cooling.
  • Check the refrigerant charge and replenish if it’s low.
  • Inspect the evaporator coil sensor, control return air sensor, and control discharge air sensor.
  • Monitor the temperature manually and report any alarms at the end of the day.

Troubleshooting Thermo King Reefer Code 32

In the world of reefer units, the Thermo King SL3000 is a reliable and popular choice. However, like any mechanical system, it can encounter issues from time to time. Two common alarm codes that may appear on the SL3000 unit are code 26 and code 32. Understanding the causes and troubleshooting these alarm codes is crucial for maintaining the optimal performance of your Thermo King reefer.

Alarm code 26 is an indicator of a problem with the electric motor. This can result from various issues such as motor overload, abnormal voltage, or a faulty motor. If you encounter this alarm code, it is recommended to check the motor’s connections and wiring for any loose or damaged parts. Additionally, assessing the voltage input and ensuring it falls within the manufacturer’s specified range is essential. If the issue persists, contacting a professional technician for further inspection and repair is advisable.

Alarm Code 32: Low Refrigeration Capacity

Alarm code 32 points to low refrigeration capacity, indicating that the reefer unit may struggle to maintain the desired cooling temperature. To address this alarm code, several troubleshooting steps can be taken.

  1. Check the refrigerant charge: Insufficient refrigerant can lead to reduced cooling capacity. It is important to ensure the refrigerant levels are within the recommended range. If the charge is low, it should be replenished by a qualified technician.
  2. Inspect the evaporator coil sensor: The evaporator coil sensor plays a crucial role in determining the temperature and regulating the cooling process. If it is malfunctioning, inaccurate temperature readings can occur. Check for any sensor damage or wiring issues that may affect its performance.
  3. Examine the control return air and control discharge air sensors: These sensors monitor the airflow and temperature within the reefer unit. Faulty or damaged sensors can disrupt the cooling process and trigger alarm code 32. Inspect these sensors for proper functioning and address any issues accordingly.

“Regular monitoring of the reefer’s temperature and reporting any alarm codes at the end of the day is essential to prevent prolonged issues and ensure optimal performance.” – Thermo King Experts

Troubleshooting alarm codes 26 and 32 on your Thermo King SL3000 reefer unit requires attention to detail and prompt action. By addressing these issues promptly and implementing the suggested troubleshooting steps, you can maintain the efficiency and reliability of your reefer unit. In complex situations or for any uncertainties, it is recommended to seek assistance from professional technicians with expertise in Thermo King reefer systems.

Troubleshooting Thermo King SL3000 Alarm Codes

Alarm Code Cause Troubleshooting Steps
26 Problem with electric motor
  • Check connections and wiring
  • Assess voltage input
  • Consult professional technician if needed
32 Low refrigeration capacity
  • Check refrigerant charge
  • Inspect evaporator coil sensor
  • Examine control return air and control discharge air sensors

Conclusion

Fixing Thermo King reefer code 32 requires a thorough understanding of the alarm codes and the reefer unit itself. By checking the refrigerant charge, monitoring the temperature, and inspecting the various sensors, one can effectively troubleshoot and resolve the issue.

Prompt repair and maintenance are essential to ensure the reefer operates efficiently. It is crucial to address any alarm codes, such as code 26 and 32, promptly to prevent any further complications and ensure the proper functioning of the Thermo King reefer.

Remember to seek professional assistance if needed, and always refer to the manufacturer’s guidelines and recommendations for troubleshooting and repairs. By following these steps, you can effectively fix Thermo King reefer code 32 and keep your reefer unit in optimal condition.

FAQ

What does Thermo King reefer code 32 indicate?

Thermo King reefer code 32 is an alarm code that indicates low refrigeration capacity in the unit.

What should I do if I see Thermo King reefer code 32?

The first step is to check the refrigerant charge of the unit. If it is low, it needs to be replenished. Additionally, the evaporator coil sensor, control return air sensor, and control discharge air sensor should be checked for proper functioning.

What other alarm code is often accompanied by Thermo King reefer code 32?

Thermo King reefer code 32 is often accompanied by code 26, which signifies poor cooling.

How can I troubleshoot Thermo King reefer code 32?

To troubleshoot Thermo King reefer code 32, it is recommended to check the refrigerant charge and replenish it if necessary. Additionally, the evaporator coil sensor, control return air sensor, and control discharge air sensor should be inspected for any issues.

Why should I monitor the temperature manually and report any alarms at the end of the day?

Monitoring the temperature manually and reporting any alarms at the end of the day allows for timely detection of any issues with the Thermo King reefer unit.

What should I do if the Thermo King reefer unit is shut down?

If the Thermo King reefer unit is shut down, immediate repair is necessary to address the issue.

Why is it important to address Thermo King reefer code 32 promptly?

It is essential to address Thermo King reefer code 32 promptly to ensure efficient and effective operation of the Thermo King reefer unit.